Dimension Parameter Defaults

The Dimension Parameters and defaults are displayed in the Dimension Selection form. Refer to Change Resource Dimensions for programming instructions.

The following table list the Dimension Parameters and defaults for the AX, CX II, CXi II, and MXe III.

Parameter Name and Range of Values

Default # of Units

Attendant Consoles (2-48)

24

Attendant Groups (2-100)

48

Broadcast Groups (12-16000)

9090

Call Reroute Always (10-250)

175

Call Reroute 1st Alt (10-500)

336

Call Reroute 2nd Alt (10-100)

32

Class of Service (10-110)

110

Default Account Codes (10-600)

225

Departments (10-5000)

2000

Digit Blocks (100,000 max.)

12056
12256 (see Note 2)

40000 (see Note 3)

DTMF Receivers (16-200)

128

DTS Service (10-300)

64

Hunt Groups (10-3000)

2000 - server-based MiVoice Business platforms
176 - all other controllers

Independent Account Codes (10-40000)

11000

Locations (10-5000)

2000

Multiline Sets (12-6000)

5755

Multiline Sets Button Dig (32766 max.)

28000

Personal Speed Call Users (10-1000)

500

Pickup Groups (10-3000)

800 - MiVoice Business platforms
200 - all other controllers

Route Lists (10-1200)

128
600 (see Note 1)

Route Plans (10-100)

32

Routes (10-2400)

200

1200 (see Note 1)

Single Line Sets (16-5000)

700

Speedcall Digit String (32766 max.)

3601/10001 (see Note 4)

System Account Codes (10-100)

24

System Digit Strings (196,000 max.)

30001
56000 (see Note 1)

170000 (see Note 3)

System Speed Call (10-10000)

1000

2000 (see Note 1)

Telephone Directory (55-130000)

20000

50005 (see Note 1)

130000 (see Note 3)

Transient Digit String (32766 max.)

20000

Trunk Groups (8-250)

112

Trunks (8-2000)

628

Trunk Service (8-500)

150

PKM Devices (2-700)

75

SUPERSET Callback Messages (48-10000)

3999

Busy Lamp Groups (2-5000)

439

Page Groups (2-400)

16/64 (see Note 5)

Suites (2-2332)

364

Linked Suites (2-1222)

500

Call History (2-65000)

56000

 

NOTES

  1. Default value when 250 Maximum Elements Per Cluster is selected.

  2. 12256 is the default value for all 700 user systems and 12256 is the default value for all for all 5600 user systems.

  3. 40001 is the maximum default value for all the 999 is the Cluster systems.

  4. 3601 and 10001 are the defaults for 700- and 5600-user systems respectively.

  5. 16 for PPC, 64 for server based.